Threshold trigger expression
When we configure the threshold alarm, we need to configure the threshold trigger expression. The system calculates whether to trigger the alarm according to the expression and the monitoring index value. Here is a detailed introduction to the use of the expression.
Operators supported by expressions
equals(str1,str2)
==
<
<=
>
>=
!=
( )
+
-
&&
||
Rich operators allow us to define expressions freely.
Note⚠️ For the equality of string, please use equals(str1,str2)
, while for the equality judgment of number, please use == or !=
Supported environment variables
Environment variables, i.e. supported variables such as Metric values, are used in the expression. When the threshold value is calculated and judged, the variables will be replaced with actual values for calculation.
Non fixed environment variables:These variables will change dynamically according to the monitoring Metric object we choose. For example, if we choose response time Metric of website monitoring, the environment variables will have responseTime - This is the response time variable
If we want to set when the response time of website monitoring is greater than 400 to trigger an alarm,the expression is responseTime>400
Fixed environment variables(Rarely used):instance : Row instance value
This variable is mainly used to calculate multiple instances. For example, we collected usage
(usage is non fixed environment variables
) of disk C and disk D, but we only want to set the alarm when the usage of C disk is greater than 80. Then the expression is equals(instance,"c")&&usage>80
Expression setting case
- Website monitoring -> Trigger alarm when the response time is greater than or equal to 400ms
responseTime>=400
- API monitoring -> Trigger alarm when the response time is greater than 3000ms
responseTime>3000
- Entire site monitoring -> Trigger alarm when URL(instance) path is
https://baidu.com/book/3
and the response time is greater than 200msequals(instance,"https://baidu.com/book/3")&&responseTime>200
- MYSQL monitoring -> status Metric group -> Trigger alarm when hreads_running(number of running threads) Metric is greater than 7
threads_running>7
Other issues can be fed back through the communication group ISSUE!